[server1]
ServerName=(local)
DBName=avt_db
Name=Quality

[common]

;number of servers connected to the PFM
servercount=1

MinSegmentHeightInPixels = 4
;0-PrintFlow utility for LCCD, 
;1- PrintFlow Manager, 
;2-Rewinder Control , 
;3- PrintFlow utility for PV
;4 - PrintFlow utility for sheets/packs
ApplicationType=0

;specifies translation file name
title=PrintFlow_Manager_Eng.txt

;use this parameter (InverseLane=1) in case the lanes order in the 
;Graphical Editing screen does not suit the lanes order on the physical roll
;default: InverseLane=0
InverseLane=0

;this parameter is used for compatability with old versions
;do not change it in the current version
Label=0

;this parameter defines the number of rolls that are shown in the press summary screen
;default: RecentlyRollCount=20
RecentlyRollCount=20
RecentlyJobCount=20

;if more than 15 lanes could be specified during job definition 0in the press, 
;then put MoreThan15Lanes=1
;default:MoreThan15Lanes=0
MoreThan15Lanes=0

;default: UseQuickConnection=0
UseQuickConnection=0

;connection timeout in seconds
;increase this parameter if the network is bad
;decrease this parameter for fast PFM application startup
;if ConnectionTimeout=0 the default values will be used
;default: ConnectionTimeout=10
ConnectionTimeout=10

UseWindowsAuthentication=0

ConnectToServerOnEachOperation=0

ShowMessageInStartIfNoConnectionToPress=1

;for packaging - in meters;  for labels - in labels
RollLengthThreshold=0

;this parameter is used for compatability with old versions
;do not change it in the current version
;1-meter; 2-feet
MeasurementSystem=1

;this parameter defines whether system will show error message in case of some Access-related problems
ShowError=0

ShowPicture=-1
RefreshButton=-1
PrintButton=-1
DeleteButton=-1
RestoreButton=-1
BackupButton=-1
FindButton=-1
StatisticsButton=-1
RollSummaryButton=-1
DefectListButton=0
DefectMapButton=0
DefectMapOnPrint =0
GraphicalEditingButton=-1
RollDeltaEButton=-1
RollSpLABButton=-1
RollRLMButton=-1
RollVarBarcodeButton=0
ShowNewRollButtonOnEdit=1
ShowWastConrollButton=0
SaveAndExitButton=1

RenameMenu=1
BackupMenu=1
RestoreMenu=1
DeleteMenu=1
FindMenu=1
SortingMenu=1
RefreshMenu=1
PrintMenu=1
PrintOnPrimeryMenu=0
StatisticsMenu=1
EditRollStatusMenu=-1
FixedBarcodeStatistics=0
DefectStatisticsMenu=0
RLMExportMenu=0
ToolsMenu=0
SynchronizationMenu=0
FlipRollMenu=0


OnlineOnlyMode=0
OnlineWindow=0
JobProofWindow=-1
SpLabWindow=0

AutomaticRefresh=-1
OnlinePollingTime=60000

SplashMessage=-1
SplashMessageDelaySec=-1

ShowJobDescription=1

ShowGradeColumnInVarBarcode=1

ShowRejectDefectReason=0

AskIncludeImages=0



;****************************************************
;*** flags for new PF Segements, Filters & Legend ***
;****************************************************
IsUnifySegmentsActive=1
UnifySegmentsFilterActive=0

;Color - A,R,G,B
UnifySegmentsBorderColor=0,0,0,0
UnifySegmentsFillColor=0,247,159,45
UnifySegmentsSelectedColor=0,168,99,6

UnifySegmentsCombinedFillColor=0,249,212,64

IsIdealSegmentsActive=0
IdealFilterActive=0

;Color - A,R,G,B
IdealBorderColor=0,255,242,0
IdealFillColor=0,190,118,119



IsMachineEventsSegmentsActive=0
PressEventsFilterActive=0

;Color - A,R,G,B
PressEventsBorderColor=0,176,30,255
PressEventsFillColor=0,190,118,119



IsMachineStartEventActive=0
MachineStartEventFilterActive=0

;Color - A,R,G,B
MachineStartEventBorderColor=0,255,15,67
MachineStartEventFillColor=0,190,118,119



IsMachineStopEventActive=0
MachineStopEventFilterActive=0

;Color - A,R,G,B
MachineStopEventBorderColor=0,12,255,190
MachineStopEventFillColor=0,190,118,119



IsManualSegmentActive=0
ManualSegmentFilterActive=0

;Color - A,R,G,B
ManualSegmentBorderColor=0,47,54,153
ManualSegmentFillColor=0,190,118,119



IsDefectSegmentActive=1
DefectFilterActive=1

;Color - A,R,G,B
DefectSegmentBorderColor=0,239,80,72
DefectSegmentFillColor=0,239,80,72
DefectSegmentSelectedColor=0,255,128,0

DefectSegment2FillColor=0,206,86,53
DefectSegment3FillColor=0,244,156,105


;Color - A,R,G,B
GoodMaterialBorderColor=0,97,167,202
GoodMaterialFillColor=0,97,167,202
GoodMaterialSelectedColor=0,227,244,168
;Color - A,R,G,B
NotInspectedMaterialBorderColor=0,226,226,226
NotInspectedMaterialFillColor=0,149,165,166
NotInsepectedMateialSelectedColor=0,203,234,232

;Color - A,R,G,B
AcceptableMaterialBorderColor=0,0,166,0
AcceptableMaterialFillColor=0,0,166,0
AcceptableMaterialSelectedColor=0,0,255,0

;Color - A,R,G,B
DefectSegmentDrMachineFillColor=0,234,210,30
DefectSegmentDrMachineSelectedColor=0,255,160,0
UnifySegmentsDrMachineFillColor=0,232,175,18
UnifySegmentsDrMachineSelectedColor=0,234,210,30

DefectAreaFilterActive=1
ShowAllFilterActive=1
OpenFilterByDefault=7
;****************************************************
 
EnableOneByOneEditing=1

UseGroupIDFiler=1


;Defect Area Param for filtering
MinDefectAreaSize=1000

IsMasterAraesImageButtonVisible=1
IsMasterZonesImageButtonVisible=1
IsDefectMapActive=0
IsInverseAccordingToSurfaceAndReversePrinting=0



;in case one defect segment contains more than 1 defect,
;this flag will disable possibility to reject the defect
;Default: DisableEditSegmentIfManyDefects=0
DisableEditSegmentIfManyDefects=0

$Use this parameter to check whether the PFM has permissions to work with files on a remote AVT computer (PV or LCCD)
$the check will take place during system start
;Default: CheckFolderPermission=0
CheckFolderPermission=0

$shows button that will open big window with master-defect pictures
ShowMasterDefectDialog=1


MultiplyPicturesPerSegment=1
DisallowUnifyAccrossLanes=1
IsLoadBarcodeTwice=0
IsBarcodeFormBeforeSensorHeightEditingForm=0


$used in case LCCD saves all distances in milimeters instead of meters
MillimetersInsteadOfMeters=0


AutomaticRefreshLogger=0

ShowOnPictureMoreThanDefectSign=1

ReadAllRLMData = 0

AdjustViewModeBoundsInGraphical=1
MouseMoveFilterTimeInMM=0
EnableLoadMasterImage=1

EnableUserAccessLevels =0
sMasterAraesImageButtonVisible=0
ConnectionSpyInterval=3
EnableConnectionSpy =0
EnableMarkAsEdited = -1
ShowDataContextUnderRoll=1

[access]
;Run = C:\Program Files\Microsoft Office\Office\Msaccess.exe
;Run=C:\Program Files (x86)\Microsoft Office\Office12
ReportFileName=reports.adp

; 0-printer; 1-DebugScreen; 2-DebugPrinter
;default: ReportMode=0
ReportMode=0

;put 1 in case the user wants the system to start automatically PDF window after each "Save to PDF" operation
;default: OpenAfterSaveToPDF=1
OpenAfterSaveToPDF=0


PrintToPDF=0

;NOT USED
PDFIniFilePath=C:\pdf995\res\pdf995.ini
PDFEnableIniFileError=1

$put 1 for Access 2007 systems (full or runtime)
$put 0 for any other system
FixAccessBug=1

MakeTrustLocation=1

PrintDefectListInsteadOfMap=-1

UseLocalRollImagesFile=0


[VirtualKeyboard]
UseVirtualKeyboard=1
VirtualKeyboardPath=c:\Apollo\Config\Misc\en.kbd

[CurrentConfig]
EditDefectMapReelResolution=7

$0-by name; 1-by date
JobSorting=0

;defines direction of material movement in the rewinder
;0 - up;  1- down;
DefectMapReelMaterialDirectionDown=0

EnableDoubleClickInDefectMap=1


[About]
1=Copyright  2000,2007
2=AVT - Advanced Vision Technology Ltd.
3=http://www.avt-inc.com

[BackupRestore]
;put 1 for checking folder permissions on AVT computer (PV or LCCD) before each Restore operation
;default CheckFolderPermissionBeforeRestore=1
CheckFolderPermissionBeforeRestore=1

[DefectPicture]
;0- close; 1- error ; 2- full log
Logger=0

ZoomMin = 1.015
ZoomMax = 4
ZoomStep=0.2
ZoomAccelerationStep=0.05

IrisMin =0.5
IrisMax = 2
IrisStep=0.05
IrisAccelerationStep=0.02

AccelerationInterval=100

$0 - use picture as it saved 
$1- make zoom to normalize picture's resolution
PixelResolutionNormalization=0

$if PixelResolutionNormalization=1, then this parameter defines 
$maximum zoom that will be used to in picture's resolution normalization
MaxZoomForPixelResolutionNormalization=3.0

;WORKFLOW LINK related parameters

[Rewinder]
;  Enable Rewinder control mode
Enable=0

; Rewinder Mode
; 0 - Normal
; 1 - Slitter/Rewinder
; 2 - Dr. Machine
; 3 - Monitor
Mode=0

; Enable Statistics mode
; 0 - Disable
; 1 - New PFM
; 2 - Old PFM
Staticstics=1

StopRewinderAtEOR=1

; Path for old PFM default value is "C:\Program Files (x86)\AVT\PrintFlow Manager 1.8.5\PrintFlowDBExplorer.exe"
PFMInstallDirectory=C:\Program Files (x86)\AVT\PrintFlow Manager 1.8.5\PrintFlowDBExplorer.exe

CleanRewinderQOnEnterRewinderState=1
Rewinder_ActivatePLC=1

;confirmation message will appear in case new roll belongs to another job or run 
;if customer does not need confirmation message put 0 
ConfirmMessageOnLoadRoll=0

;intended to make available Barcode Map button 
;default: DebugShowBarcodeMap=0
DebugShowBarcodeMap=0

;inverting roll before loading
InvertRoll=1

;1- disabling "Invert Roll" check box
;default: DisableInvertRoll=0
DisableInvertRoll=1

;minimal distance between defects to stop the rewinder
;in mm
;default:GotoPositionListMinDistance=1500
GotoPositionListMinDistance=0
	
;in mm
DefectQueueDistance=20000

;days to look for barcode
LookForBarcodeDays=60

;flag for stopping at the beginning of View Mode segments
StopAtNonInspectedMaterial=1

ServerName=(LOCAL)
DBName=WFL_TEST
Job=2
Run=0
Roll=2

;intended to make available Distances Correction Dialog
;default: DebugDistCorrectionDialog=0
DebugDistCorrectionDialog=0

RunButton=1
JogButton=1
StopButton=1
EditRollInfoButton=0
BypassAllButton=0
ManualLoadRollButton=0
NormalizationFactorButton=0
ShiftButton=1
BarcodeReaderRestartInMenu=0
ResynchToMeterButton=0

EjectorMode =0

;START LeoMat rewinder in RAKO - "SPLICE" feature

;activates the feature and shows 2 buttons
SpliceButtons=0

; show manual waste button
ShowManualWasteButton=1

; show tree view button in rewinder
ShowTreeViewInRewinder=0

;distance between inspection table and cut(splice) place 
;in mm, always positive
SpliceDistanceMM=7500

;the max tolerance distance between target and actual stop when we want to stop on a cut mark
;in mm
SpliceStopPositionTolerance=120

;END LeoMat rewinder in RAKO - "SPLICE" feature

;shows the splice to subroll button
SpliceToSubRoll=0

;shows the stop on slitter button
StopOnSlitterButton=0

; distance from inspaction table to location of splice to sub rolls
SubRollSpliceDistanceMM=0

; distance from inspection table to location of roll sticking station - default 0
RollStickingDistanceMM = 0

ShowDiagnosticsDialog=0

;in case of rewinder position shift, it is better to shift the last barcode only, 
;but in case of one barcode, if this does not work,
;it is possible to specify this flag to shift all "barcodes"
MakeAShiftToAllBarcodes=1


;if wrong barcode error appears more then MaxAllowedWrongBarcodeErrorNumber then error message will appear
;valid only if ManualLoadRollButton=1
;0 means no restriction 
MaxAllowedWrongBarcodeErrorNumber=0


;if wrong barcode appears in another order more then MaxAllowedWrongOrderErrorCount then error message will appear. 
;Valid only if ManualLoadRollButton=1
;0 means that each time when barcode appears in the another order, the error message will appear
MaxAllowedWrongOrderErrorCount=0

NormalizationFactorValue=1

; Start Loggers

Log_WFLControl=0
Log_BarcodeSearch=0
Log_GetRewinderLocationFunction=0
Log_RewinderUnify=0
SpliceLogger=0

; End Loggers


UseLocalBarcodeDB=0
BarcodeDBServerName=(local)
BarcodeDBDBName=avt_db

MISActive=0
MISServerName=localhost
MISPortNumber=80
MISSpaceName=MIS

;this is a flag for the new mode - "labels counting" (instead of meter counting)
UseLabelCountMode=0
ManualBarcodeIdentification=0

;0 - regular (old) with RPG
;1 - Label sensor (only)
;2 - Label sensor or Optic sensor
;RewinderCountingMode=1


DistCorrectionNonInverse_LCCD_AVT_DB=0
DistCorrectionInverse_LCCD_AVT_DB=0

HideSelectRollDialogInCaseOnlyOneRollExists=1

IsRewinderStopsOnUnifySegments=1
IsRewinderStopOnIdealSegment=0
IsRewinderStopOnManuelSegment=0
IsRewinderStopOnMachineEventSegment=0
IsRewinderStopOnMachineStartEventSegment=0
IsRewinderStopOnMachineStopEventSegment=0
IsRewinderStopOnBrailleSegment=0

AvoidCallingDBDuringWFL=0
IsAdditionalTrimActive=0
AdditionalTrim=10

[MasterImages]
MaxLenght=1500

[SystemScreens]
NumberOfScreens = 1

[EmailConfiguration]
SmtpHostname=smtp.avt-inc.com
EmailUsername=
EmailPassword=
EmailFrom=PfmSystem@printing-company.com
EmailTo=manager@printing-company.com
SendAsSmtp=0