[Jog To Stop Dialog]
NumInstructions=4
Instruction1=Stop the rewinder.
Instruction2=Run the rewinder at jog speed.
Instruction3=Press the 'Test' button.
Instruction4=Wait until the 'Test' button is enabled.

[From Run To Jog Dialog]
NumInstructions=4
Instruction1=Run the rewinder at maximum practical working speed.
Instruction2=Press the 'Start' button. At this stage the system will stop the machine.
Instruction3=In the "distance" edit box you will find how long the web is moving from running to a final stop.
Instruction4=Press the "Ok" button in order to save the results.

[Head Inspection Table Distance Dialog]
NumInstructions=8
Instruction1=Stop the rewinder.
Instruction2=Set the rewinder to a very low speed (jogging).
Instruction3=If possible, put a sticker on the edge of the web exactly under the optic head (Jump to step #5). If it's not possible, put it on a visible and accessible spot before the optic head and proceed to the next step.
Instruction4=Click the "Run/Stop Rewinder" button to slowly start moving the web.
Instruction5=Click the "Start Recording" button exactly as the sticker is under the optic head in order to start measuring the distance (The button will be changed to "Stop Recording").
Instruction6=Click the "Stop Recording" button as the sticker is reaching the middle of the "inspection table". (The exact distance appears in the "Distance" box).
Instruction7=If OK, click the "Run/Stop Rewinder" to stop the rewinder.
Instruction8=Click the "OK" button in order to save the result.

[Host Machine Vision Distance Dialog]
NumInstructions=1
Instruction1=Enter the vision distace as shown in the host machine.

[Errors]
2061=Initial speed could not be reached...
2062=Target speed could not be reached...
2063=Unknown Error...
0=Test OK.


[Distance to Splicer]
NumInstructions=8
Instruction1=Stop the rewinder.
Instruction2=Set the rewinder to a very low speed (jogging).
Instruction3=If possible, put a sticker on the edge of the web exactly under the optic head (Jump to step #5). If it's not possible, put it on a visible and accessible spot before the optic head and proceed to the next step.
Instruction4=Click the "Run/Stop Rewinder" button to slowly start moving the web.
Instruction5=Click the "Start Recording" button exactly as the sticker is under the optic head in order to start measuring the distance (The button will be changed to "Stop Recording").
Instruction6=Click the "Stop Recording" button as the sticker is reaching the splice position (the rewind roll).
Instruction7=If OK, click the "Run/Stop Rewinder" to stop the rewinder.
Instruction8=Click the "OK" button in order to save the result.